In short
- Four-stage clearance is required after licensed removal, carried out by an analyst from an organisation accredited by UKAS.
- The air test passes when fibre levels are below the clearance indicator of 0.01 fibres per cm³.
- HSE strongly recommends the building owner or client appoints the analyst directly, not the removal contractor.
- Air tests are also used for reassurance after an incident or during work nearby.
The four stages
HSE's analysts' guide (HSG248) sets out the four-stage clearance procedure.
- Preliminary check of site condition and job completeness. The analyst confirms the agreed removal has been done, the enclosure is intact and the surrounding area is clean.
- Thorough visual inspection inside the enclosure. Every surface is inspected for remaining asbestos debris or dust. Nothing should be visible.
- Air monitoring. Air is sampled inside the enclosure while surfaces are disturbed, for example with a brush or fan. The result must be below the clearance indicator of 0.01 fibres per cm³.
- Final assessment after the enclosure is removed. The analyst checks the area once the enclosure and equipment have gone, then issues the certificate for reoccupation.
Other types of air monitoring
- Background monitoring before work starts, to record existing levels.
- Leak and reassurance monitoring during licensed work, outside the enclosure, to check nothing is escaping.
- Reassurance testing after an incident such as accidental damage, alongside inspection and cleaning.
- Personal monitoring of workers' exposure, which is the contractor's responsibility.
Why the analyst should be independent
HSE strongly recommends that the analyst for site clearance is independently sourced and employed by the building owner or client in control of the premises, and that contractors and laboratories are UKAS-accredited. If the removal contractor appoints the analyst, the person signing off the work is effectively working for the firm being checked. Ask for the analyst's organisation and UKAS accreditation number before work starts.
What you should receive
A certificate for reoccupation covering all four stages, naming the analyst and organisation, with air test results, the location and extent of the area cleared, and the date. Keep it with your asbestos records.
Four-stage clearance across Surrey and north-east Hampshire
We introduce clients to UKAS-accredited analysts for clearance and air testing in Guildford, Leatherhead and Ashtead, Weybridge and Walton-on-Thames, Cobham and Esher, Epsom and Ewell, Woking, Dorking, Farnham, Godalming, Camberley and the rest of the areas we cover. Book the analyst before the removal starts, so the clearance can follow straight on and the area is not left sealed for longer than necessary.
Questions people ask
Is a clearance certificate needed after non-licensed work?
Four-stage clearance is required for licensed work. After non-licensed work, a thorough visual inspection and sometimes reassurance air testing are good practice, particularly in homes, schools and offices.
Can an air test tell me if my house is safe after DIY damage?
A reassurance air test can measure airborne fibres at that moment, but settled dust and debris also need to be found and cleaned. Start with an inspection; the analyst will advise whether air testing helps.
What happens if the area fails?
The contractor must clean again and the failed stage is repeated until it passes. A failure is not unusual and is exactly why the check exists.